Search results
1 – 2 of 2Xiaohua Li, Yi Shao, Weixing Miao, Yongchang Liu, Zhiming Gao and Chenxi Liu
The purpose of this paper is to focus on the galvanic corrosion behaviors of the low-carbon ferritic stainless steel electrical resistance welding (ERW) joint in the simulated…
Abstract
Purpose
The purpose of this paper is to focus on the galvanic corrosion behaviors of the low-carbon ferritic stainless steel electrical resistance welding (ERW) joint in the simulated seawater.
Design/methodology/approach
The electrochemical methods such as electrochemical noise, galvanic current and TOEFL polarization curve tests were used to study the galvanic corrosion behaviors of ERW joints of low-carbon ferritic stainless steel in simulated seawater. On this basis, a reliable accelerated corrosion method was developed.
Findings
The corrosion type of the base metal and joint is the typical local corrosion. The order of corrosion resistance from strong to weak is: weld zone > base metal > low-temperature heat-affected zone (HAZ) > high-temperature HAZ. The results of constant current-constant potential accelerated corrosion test show that after constant current-constant potential accelerated corrosion, the joints present a typical groove corrosion pattern. The groove initiating area is located in the HAZ, and the corrosion degree in the weld zone is relatively light, which is consistent with the electrochemical test results.
Originality/value
This paper has clarified the galvanic corrosion behaviors of low-carbon ferritic stainless steel ERW joints. Moreover, a reliable accelerated corrosion method for the low-carbon ferritic stainless steel ERW joint has been developed.
Details
Keywords
Jun Ni, Jifei Dong, Jingchao Zhang, Fangrong Pang, Weixing Cao and Yan Zhu
– The purpose of this paper is to improve the accuracy and signal-to-noise ratio (SN) of a crop nitrogen sensor.
Abstract
Purpose
The purpose of this paper is to improve the accuracy and signal-to-noise ratio (SN) of a crop nitrogen sensor.
Design/methodology/approach
The accuracy and wide adaptability of two spectral calibration methods for a crop nitrogen sensor based on standard reflectivity gray plates and standard detector, respectively, were compared.
Findings
The calibration method based on standard detector could significantly improve the measurement accuracy and the SN of this crop nitrogen sensor. When compared with the method based on standard gray plates, the measurement accuracy and the SN of the crop nitrogen sensor calibrated based on the standard detector method improved by 50 and 10 per cent, respectively.
Originality/value
This research analysed the calibration problems faced by the crop nitrogen sensor (type CGMD302) based on standard gray plates, and proposed a sensor calibration method based on a standard detector. Finally, the results of the two calibration methods were compared in terms of measurement accuracy and the SN of the crop nitrogen sensor.
Details